2026-11-27

Sage 100: DYMO Printer Does Not Hold Paper Size Setting When Printing Labels

Sage 100: DYMO printer does not hold the paper size setting when printing labels — 30256 prints as 30252. The documented remedies, in the order to try them.

The symptom: Labels from a DYMO LabelWriter 450 print on the wrong size. You load 30256 Shipping labels, but the output renders as though the smaller 30252 label were selected — the content shrinks, spills across two labels, and the run is wasted. Open the printer setup before printing and the correct 30256 size is sitting there; print after checking and the label is perfect. Print again without checking, and it reverts. The wrong size is not specified anywhere you can find — not in the form, not in the saved report settings.

This behavior typically starts with an upgrade. Sites that printed labels happily for years on Sage 100 4.4 met it after moving to Sage 100 2014, because the newer printing path does not hand the paper size to the DYMO driver the way the old one did.

The fix

Sage does not support or test thermal/label printers for Sage 100 (Sage KB 224924250053868), and there is no verified fix in the original DYMO thread. The remedies below are the ones documented by Sage 100 consultants who worked this problem on 2014:

  1. Get current on product updates first. Earlier Sage 100 2014 product updates had a defect retaining proper label size; a consultant who hit this reports it "magically went away during one of the product updates." Install the latest product update for your 2014 release and test two consecutive label prints without opening printer setup in between.
  2. Do not use the standard Sage label template. Create the label form from scratch in Crystal Reports Designer as a standard report type — not a mailing-label template — using the label-printing work tables. Set the paper size to your label stock (e.g. 30256 Shipping) and format the label. In Sage, let label printing create its default label form, then copy your from-scratch form over that default form.
  3. Assign the printer inside the form. Open the form in Crystal Reports Designer, Page Setup, select the check box under Printer Options, assign the DYMO LabelWriter, and set the 30256 paper size. Save the form.
  4. Set the Windows default as a secondary pin, not the cure. In the DYMO printer's Printing Preferences > Advanced, set 30256 as the default paper size, on the workstation and, if the printer is shared, on the host. Note: in the original reported case this was already done and did not by itself hold the size — do not stop here.
  5. Do not rely on deleting saved report settings. Deleting and recreating the saved settings for the form code was tried in the original case and reported as "No go." It is a diagnostic, not a fix.
  6. Interim workaround that is proven in the original case: before each label run, open Setup > Preferences > Advanced and confirm the 30256 size. Prints made immediately after viewing the preference used the correct size; the next print without that step reverted.
  7. Retest exactly as the fault occurs: print one label, then print a second label — and a second copy — without opening setup. One good print proves nothing with this fault.

Causes

Label printers sit outside Sage 100's supported printing

Sage does not support or test thermal and label printers for Sage 100 (Sage KB 224924250053868). Forms for these printers usually have to be heavily modified in Crystal Reports Designer to customize paper size and alignment to the exact brand, model, and label stock — minute adjustments and extended iterations of trial-and-error — and Sage Support does not assist with custom Crystal forms. There is no single Sage setting that makes a label printer hold its size.

A 2014 product-update defect in retaining label size

Consultants who worked this problem on Sage 100 2014 traced part of it to the release itself: earlier 2014 product updates had an issue retaining the proper label size, and the problem disappeared for at least one site during a later product update. Nothing about your labels, form design, or printer changed in the upgrade — which is why a setup that was stable for years on 4.4 can break the week the version changes, and why getting current is step 1 of the fix rather than an afterthought.

The standard label templates

The label forms Sage creates by default are part of the problem. Experienced label-printing sites build their own form from scratch — a standard report type, not a mailing-label template — and copy it over the default form, rather than fighting the template's paper-size behaviour.

Per-context variants

First label right, second label wrong: the same retention failure inside a single run. Even two copies of one label can disagree, because the size is applied to the job, not held by the driver.

One workstation only: compare that machine's Windows defaults and driver version against a workstation that prints correctly. Workstation-specific label problems are almost always local driver settings, not Sage data.

Other thermal printers: Sage does not officially support or test thermal and label printers, and Zebra and Brother QL devices show the same class of behavior. Expect the form to need careful Crystal-level sizing work for the exact label stock, and expect to pin settings at the driver level.

Affected versions

Documented on Sage 100 ERP 2014 with a DYMO LabelWriter 450, immediately after upgrading from 4.4, using 30256 Shipping labels reverting to 30252. The pattern is reported on other workstations and label forms of the same era.

If the fix doesn't work

  • Lean on the interim workaround in step 6 while you schedule the deeper work below. It is tedious, but it is reliable, and it keeps shipping moving.
  • Reinstall the DYMO driver cleanly and re-create the printer in Windows, then re-apply the Windows default size. A driver carried through an operating system or Sage upgrade can hold stale defaults that no settings screen will overwrite.
  • Test the form with the printer assigned inside it (step 3) on a second workstation. If it holds there, rebuild the failing workstation's printer setup rather than editing the form again.
  • Check SY_ReportSetting only to confirm what Sage saved — the absence of the paper size there is expected and is itself the clue that the size must come from the form and driver.

Prevention

After any Sage 100 upgrade, re-test label printing before the first production run: install the latest product update, confirm your from-scratch form is in place with the printer assigned inside it, and run a two-label test print without opening setup. Label printing is the first casualty of print-path changes, and a five-minute test on upgrade day beats a wasted roll of labels on shipping day.